All claims made by manufacturer
COMPANY MODEL DESIGN ILLUMINATION
AMA Optics Inc. Retinal Acuity Meter-RAM Handheld, stand alone High illumination
FIELD
COMPANY MODEL TYPE OF VIEW
Escalon Digital E6 Single digital conversion of any
Solutions mydriatic fundus
camera
Escalon Digital E6 Dual digital conversion of any
Solutions mydriatic fundus
camera
Escalon Digital E11 digital conversion of any
Solutions mydriatic fundus
camera
Kowa Genesis D joystick w/auto- 30° horizontal
Optimed Inc. Handheld Fundus firing and infrared
Camera measuring
Kowa Genesis Df joystick w/auto- 30° horizontal
Optimed Inc. Handheld Fundus firing and infrared
Camera measuring
Kowa nonMyd 7 compact; tabletop; nonmydriatic
Optimed Inc. Fundus Camera nonmydriatic color 45º/20º
Kowa nonMyd compact; tabletop; nonmydriatic
Optimed Inc. Alpha-D III nonmydriatic color 45º/30º
Retinal Camera
Kowa VX-10(a) compact tabletop;
mydriatic:
Optimed Inc. Two-in-One mydriatic;
50º/30º
Fundus Camera nonmydriatic nonmydriatic:
color/FA 45º/27º
Marco RTA-5 digital composite 72x60º
Retinal Thickness
Analyzer with Digital
Fundus Imaging
Nidek Inc. AFC-210/230 table top, 45º
Pro Photographer non-mydriatic
OIS OIS EyeScan anterior and posterior 40º
portable camera
OIS Winstation digital conversion of any
Essential mydriatic fundus
camera
OIS Winstation digital conversion of any
Retina mydriatic fundus
camera
OIS Winstation digital conversion of any
5000 mydriatic fundus
camera
OIS Winstation digital conversion of any
11K mydriatic fundus
Topcon Medical TRC-NW8 nonmydriatic 45°
Systems
Topcon Medical TRC-NW300 nonmydriatic 45°
Systems
Topcon Medical TRC-50DX/ digital/film 20°; 35°; 50°
Systems TRC-50DX ICG mydriatic
Topcon Medical TRC-NW7SF digital, hybrid mydriatic 30º, 45º, 50º
Systems & non-mydriatic
Visual ARIS 110 digital; autostereo; non & twenty-six
Pathways Inc. mydriatic retinal imaging 30º fields=120º
system (4.0 mm pupil for on retina
“semi-auto” mode)
Visual ARIS RSVP Remote Stereo Viewing n/a
Pathways Inc. Platform
RETINAL ACUITY METER
OPTICS CALIBRATION COMPONENTS SPECIAL FEATURES
CCFT Automatic Meter, Carrier Frames The RAM uses bright, calibrated illumination, exact distance & 1-mm pinhole apertures to accurately measure
Convergent light Pinhole Clip, Occluder retinal acuity; assesses macular function & forecasts postoperative vision. Prevents unnecessary surgeries &
reduces unexpected poor outcomes. Reproducible & easy.
RETINAL CAMERAS
ANGIO- NUMBER/TYPE FLASH VIDEO
GRAPHY OF PORTS STIMULUS CAPACITY ADDITIONAL FEATURES
yes n/a n/a n/a Digital imaging for most mydriatic fundus camera; 6 MP CCR sensor for excellent image quality in a single
cameraback; calibrated measurement tools; Auto Eye-Map montage feature; DICOM-compliant; integrates
with PACS and OphthaVision AXIS for side-by-side review of images from different modalities.
yes n/a n/a n/a Digital imaging for most mydriatic fundus camera; Dual 6MP CCR sensors dedicated for color and monochromatic to provide
the highest quality color images and angiograms; calibrated measurement tools; Auto Eye-Map montage feature; DICOM-
compliant; integrates with PACS and OphthaVision AXIS for side-by-side review of images from different modalities.
yes n/a n/a n/a Digital imaging for most mydriatic fundus camera; 11 MP CCR sensor for specialized settings; calibrated
measurement tools; Auto Eye-Map montage feature; DICOM-compliant; integrates with PACS and OphthaVision AXIS
for side-by-side review of images from different modalities.
yes 1 primary port; USB 2.0 n/a no still; Compact flash memory; LCD monitor for picture review; color mydriatic photography; indirect lens holder
digital interface digital only accessory; VK-2 digital imaging system; EMR connectivity; DICOM; JPG and BMP export for telemedicine;
connection to portable notebook computer as well as desktop.
yes 1 primary port; USB 2.0 n/a no still; Fluorescein angiography (FA) photography; compact flash memory; LCD monitor for picture review; color mydriatic
digital interface digital only photography; indirect lens holder accessory; VK-2 digital imaging system; EMR connectivity; DICOM; JPG and BMP
export for telemedicine; connection to portable notebook computer as well as desktop.
yes 1 primary port; 1-6.1 n/a no still; LCD monitor for alignment and focusing; small-pupil mode; preset flash exposures; nonmydriatic color photography;
mega pixel camera back digital only camera has internal working distance and focusing dots; with VK-2 digital imaging system; EMR connectivity; DICOM;
w/USB 2.0 digital interface JPG and BMP export for telemedicine; offers connections for both portable notebook and desktop computers.
yes 1 primary port; 1 USB n/a no still; LCD monitor for alignment and focusing; small-pupil mode; preset flash exposures; color photography; nonmydriatic
2.0 digital interface digital only color photography; fluorescein angiography (FA) photography; red-free photography; camera has internal working distance
and focusing dots; VK-2 digital imaging system; EMR connectivity; DICOM; JPS and BMP export for telemedicine.
Ideal for telemedicine applications as it offers connections to both portable notebook and desktop computers.
yes 2 primary ports; n/a no still; LCD monitor for alignment and focusing; small-pupil mode; preset flash exposures; color photography; nonmydriatic color
Upper = digital digital only photography; fluorescein angiography (FA) photography; red-free photography; camera has internal working distance and
interface/35 mm/ focusing dots; VK-2 digital imaging system; EMR connectivity; DICOM; JPG and BMP export for telemedicine.
Polaroid
no digital n/a yes Versatile and modular imaging system offers a wide range of comprehensive diagnostic testing for early detection and
effective monitoring of diabetic retinopathy, AMD, other retinal pathologies, and glaucoma. Capabilities include: retina &
disc imaging with individual slit-analysis, quantified topography and 3D disc topography, thickness analysis and RNFL
thickness measurement, objective progression analysis with automated image registration for consistent comparative
analysis, Dynamic 3-D anatomy imager across full scan area with video presentation capture, and a wellness screening
program. Upgrades include: Remote RTA viewer stations and extended customer support programs.
no 2 USB 1 W/s to 25 W/s yes 12.8 megapixels for detection of diabetic retinopathy, auto-focus & auto alignment on y-axis or x-y-z axis.
1 RGB Small-pupil mode, stereo mode, montage capability.
yes n/a yes yes
The OIS EyeScan is the only portable imaging device that gives practices the ability to image both the anterior and
posterior segment of the eye. With color retinal imaging, fluoresce in angiography, stereo optic nerve head imaging,
tear film, red reflex and topical fluorescein imaging modules, the OIS EyeScan is unmatched in quality and
comprehensive imaging capabilities.
yes n/a n/a n/a Designed to meet the needs of general ophthalmologists by delivering a good quality image ideal for primary
documentation purposes through the use of its 3.2 megapixel sensor. Using OIS Symphony, images can be enhanced
and reviewed side by side with imported ophthalmic diagnostic reports produced by other devices in the clinic. Single-
click integration with different EMR systems can be provided.
yes n/a n/a n/a With its 5.3 megapixel sensor, it’s designed to meet the needs of retina specialists who require excellent image quality
with more detail for a higher level of diagnostic ability than general ophthalmologists require. Using OIS Symphony,
images can be enhanced and reviewed side by side with imported ophthalmic diagnostic reports produced by other
devices in the clinic. Single click integration with different EMR systems can be provided.
yes n/a n/a n/a With its 35-mm, 6-megapixel CCD, it’s designed to meet the needs of more demanding retina specialists who require
the best image quality available. Using OIS Symphony, images can be enhanced and reviewed side by side with imported
ophthalmic diagnostic reports produced by other devices in the clinic. Single-click integration with different EMR systems
can be provided.
yes n/a n/a n/a With its 35-mm, 11-megapixel CCD, it’s designed for research & teaching institutions that demand the most detailed images
on the market today. Using OIS Symphony, images can be enhanced and reviewed side by side with imported ophthalmic
diagnostic reports produced by other devices in the clinic. Single-click integration with different EMR systems can be provided.
no 1 std: digital CCD 6 W/s to 27 W/s yes Color fundus with unique red-free imaging. High quality 12.1 megapixel images with Nikon digital camera. Auto focus,
auto capture, auto small pupil detector, stereo mode, and Auto Mosaic
. Can be combined with Topcon’s IMAGEnet
Lite and
EyeRoute
®
Systems for image management and networking. Compatible with today’s most popular EMR systems.
no digital CCD 3.3 W/s to 13 W/s yes 8 megapixel built-in capture device; auto focus, auto exposure and auto shoot; direct printout to digital printer; can be
built-in combined with Topcon’s IMAGEnet
Lite and EyeRoute
®
Systems for image management and networking. Compatible
with today’s most popular EMR systems.
yes 2 std: 35 mm 12 W/s to 300 W/s n/a Digital-ready; can accept a variety of photo devices; Color fundus, red-free & fluorescein filters. Autofluorescence & ICG
or digital CCD filters also included on TRC-50DX ICG. Touch-screen control panel; 21 flash settings; small pupil mode; can be connected to
Topcon’s IMAGEnet system.
yes 1 35 steps from no no Color, red-free and fluorescein capabilities in one device. Medical grade imaging sensor provides consistent color rendition;
flash to 300Ws swing and tilt movement allows for precise peripheral capture; capture images through undilated pupils as small as 3mm
(in color non-myd mode only); intuitive to use with Topcon’s user-friendly, ergonomic camera design; seamless integration
with EyeRoute Image Management System.
no 4 USB; RS232; ethernet; 35 W/s to 40 W/s no Fully automated; pupil-tracking; exposure & focus; telecentric optics; Constant Base Stereo; filter selection for IR, red 1,
printer; sound card red 2, red-free & color images; BichromaticImage Navigation; optional glaucoma detection & evaluation S/W internet ready.
New automatic glaucoma detection & evaluation (GDE) software module available as option, featuring Constant
Base Stereo™.
n/a n/a n/a n/a Includes PC, monitor, ArisWare software; stereo emitter & two pair viewing glasses for hands-free
stereo viewing of ARIS™ stereo images.