All claims made by manufacturer
COMPANY MODEL STIMULUS AREA OF FIELD
Haag-Streit Octopus 900 100% total fixation control; 90º in
USA BASIC no fixation losses on printouts; Goldmann
video eye monitor and chin rest spherical bowl
sensor; Goldmann standard
projection I, II, III, IV, V
Haag-Streit Octopus 900 Same as BASIC + unique auto 90° in
USA PRO eye tracking; one system Goldmann
offering standard static spherical bowl.
white/white + blue/yellow +
Flicker + TRUE Goldmann
Kinetic + low vision + red/white.
Haag-Streit Octopus 300 100% total fixation control - 30º direct
USA BASIC no fixation losses on printouts; projection;
video eye monitor and forehead far distance
rest sensor; Goldmann standard correction
projection III, V; operates in only needed.
diffused room lighting
Haag-Streit Octopus 300 Same as BASIC + unique auto Same as BASIC
USA PRO eye tracking; one system offering
standardized static white/white +
blue/yellow + Flicker + low vision
Haag-Streit Goldmann True Goldmann I thru V + 1-4/a-e. Software package
USA Kinetic Control speed of 0 (static) or to 900 Basic (option)
2/3/4/5/10 degree per second or & Pro (standard).
free form
Haag-Streit EyeSuite EyeSuite Lite; Archive perimetry
USA Software EyeSuite Advanced; data with single
Analysis EyeSuite Pro field analysis.
program
Kowa AP-5000C Goldmann std. proj. size 80º
Optimed Inc. II-V, Heijl-Krakau Eye fixation
monitor
Oculus Inc. Centerfield II Goldmann size II; Heijl-Krakau 70°
& central fixation; video eye
monitor; static white-on-
white & blue-on-yellow;
auto kinetic
Oculus Inc. Twinfield Goldmann size I–III; Heijl-Krakau 90°
& central fixation; video eye
monitor; static white-on-white,
blue-on-yellow & red-on-white;
auto & manual kinetic
Oculus Inc. Easyfield Goldmann size III; Heijl-Krakau 30°
& central fixation; video eye
monitor; static white-
on-white
OPTOPOL PTS 1000 Goldmann size I-V white, blue, 100º (160 with
Technology S.A. red, green fixation shift
(distributed by Canon horizontally)
Medical Systems)
Paradigm Medical TKS 5000 static w/kinetic ±90°
Industries Inc. autoperimeter fixation; Heijl-Krakau
Dicon Inc. fixation monitor
Paradigm Medical LD 400 static w/kinetic ±60°
Industries Inc. autoperimeter fixation; Heijl-Krakau
Dicon Inc. fixation monitor.
Paradigm Medical FieldLink static w/kinetic ±60°
Industries Inc. Automated fixation; Heijl-Krakau
Dicon Inc. Perimetry fixation monitor.
System
Paradigm Medical LD 700 Goldmann size III; 30°
Industries Inc. Heijl-Krakau; red LED
Dicon Inc. fixation targets, static
Reichert Foresee PHP Dot deviation signal flashed Central visual
Technologies over macular Ioci field - 14º
Woodlyn/Medmont M700 Goldmann Size III - pale green 80º
rear projection LED (red macula
stimulus optional) 15 points x 3dB
steps / 45 points x 1dB steps -
video fixation monitoring feature
PERIMETERS
STANDARD TESTS PRINTER TEST STRATEGIES ADDITIONAL FEATURES
diagnostic thresholds for Perimeter controlled by TOP (tendency oriented Automatic pupil measurement; automated lens holder; stimuli presentations are
glaucoma & macula; linear PC/monitor & ink jet perimetry) for thresholds adaptive to patient responses; easily upgraded to 900 PRO series; wheelchair-
32 & macula threshold; low printer (all provided); in just over 2.5 minutes per accessible table provided; easily integrated with electronic medical records.
vision; neurological; diabetes EyeSuite Lite Software eye; dynamic; normal - all
blepharoptosis; multiple provided for long-term age related; 1 and 2 level
screening tests, including storage & data analysis; screening tests with
glaucoma & 130 point easily networked; viewing supra-threshold
screenings stations - no charge. EZ
to read 7 in 1 printout.
Same as BASIC + unique Same as BASIC + Same as BASIC Same as BASIC
custom testing allows you Full 3-level EyeSuite
to build what you want software provided for
where you want it. long-term storage
and data analysis.
Diagnostic thresholds for No outdated processor built in; TOP (Tendency Oriented Perimetry) Automatic pupil measurement; stimuli presentations are adaptive to patient
glaucoma and macula; easy to read 7-in-1 printout; for thresholds in just over 2.5 responses; easily upgraded to 300 PRO series; wheelchair-accessible table
linear 32 threshold; low auto print and/or export to minutes per eye; dynamic; normal (either compact or universal sized) available; easily integrated with
vision; multiple screening our EyeSuite Lite/Advanced/Pro - all age related; 1 and 2 level electronic medical records using available EyeSuite Software package.
tests, including 30 second (available) to your own screening tests with
per eye; 1 minute per eye PC for long-term storage supra-threshold
& data analysis; easily
networked; no add’l
charges for viewing stations.
Same as BASIC + custom Same as BASIC + all 3 Same as BASIC Same as BASIC
testing to build muliple levels of EyeSuite
examinations (Lite/Advanced/Pro) are
provided.
Build ANY kinetic test needed & n/a Manual or automated Goldmann Quantification of kinetic isoptors for easy comparison; field correction based on
save to library for perfectly Kinetic; use of automated, reaction time of patients response; zoom function to plot selected areas
repeated tests every time guided or free vectors that can be used in combination with static perimetry.
EyeSuite Lite standard on n/a n/a Easily networked w/no extra charges for viewing stations; easily integrated
900 Basic & 300 basic; w/electronic medical records. Archive perimetry data w/single-field analysis-lite
EyeSuite Lite, Advanced & Pro + cluster trend analysis structure function graph + pro superposition
standard on 900 & 300 Pro images/fields. New cluster and polar graphs.
25 test programs including External PC threshold: IQAC aged reference In ocular fundus perimetry, the visual field is examined w/an ocular fundus image
threshold: Center 1 & 2, macula, connected screening 2,3,4 zone & quantify displayed on screen. System offers capability to overlap ocular fundus image
periphery & meridian; screen- defects & perimetry result so physician can better understand the retinal function.
ing: standard or precision; isopter:
Goldmann & automatic perimeter
is combined
30°; 10° macula; 30°course; optional 3 suprathreshold; new CLIP Portable; compares exams; stats pkg.; progressive display; combo stats & kinetic
36°–70°; 70°; 0°– 36°; threshold; fast threshold; 1 full display; color display; exam indep. of room light; free software upgrd.;
sgl. pts. -36°; sgl. pts.-70°; threshold 4/2; qdrnts; sgl. pts.; adj. test pt. duration & intervals; 30-cm radius bowl; Goldmann std.; measures
36° sectors; 10-2; 24-2; user-defined pupil size; trial lens holder; CLIP strategy for faster visual field exam.
30-2 quick screen
all of the above plus optional 3 suprathreshold; new CLIP Compares exams; stats pkg.; progressive display; combo stats & kinetic disp.; color
indiv. test pts.; central threshold; fast threshold; 1 full of room light; free software upgrade; adj. test pt. duration & intervals; 30-cm radius
& entire field threshold 4/2; qdrnts; sgl. pts.; bowl; Goldmann std.; measures pupil size; trial lens holder. CLIP strategy for faster
user-defined visual field exam.
10-2; 24-2; 30-2; built-in 3 suprathreshold; fast Less than 12 lbs; portable; stats pkg.; CCD camera; moveable headrest & cone/bowl;
preprogrammed threshold; full color LCD display; stores 40,000 exams; screening rslts. 50–70 secs.; 30-cm radius
quick tests threshold 4/2; qdrnts; bowl; free software upgrds.; exam indep. of room light; measures pupil size.;
sgl. pts. trial lens holder; two models; built-in console/computer; can use newer model
w/own PC or laptop. CLIP strategy for faster visual field exam.
Accurate threshold, Intelligent Printout manager with Kinetic, screening, threshold, Eye monitoring by means of built-in video camera. Advanced auto-detection of eye
advanced threshold, screening predefined printout 3-zone, fast threshold, BSV (binocular position. Automatic pupil diameter measurement. Automatically controlled chin-rest
and quick 3-zone styles single vision), flicker (critical fusion enables you to set proper patient’s position precisely and easily. Printout manager
frequency), blue on yellow (SWAP), with predefined printout styles. Network capabilities (remote database, networked
BDT (Binocular Drivers Test), advanced review stations). Direct database back-up. Special ventilation system is used to keep
- reduced field option fresh air throughout examination inside stimulation bowl.
- neurological defects option
10°, 30° & 60° Inkjet std.; color threshold-related suprathreshold Supported by Adv. FieldView Omega Analysis software; disk storage; FieldLink
field patterns; printer support w/ screening; quantify missed pts.; upgradable; voice recognition; voice prompts.
13 programs std. Fieldview. full threshold; HT
10°, 30° & 60° Inkjet std.; color threshold-related suprathreshold Half the size of TKS 5000 w/full-field capability; fits on rotating table; supported by
field patterns; printer support w/ screening; quantify missed pts.; FieldView Analysis software; disk storage; voice management; voice prompts;
13 programs std. Adv. FieldView. full threshold; HT Advanced FieldView w/Fieldview download to PC.
10°, 30° & 60° Inkjet std.; threshold-related suprathreshold Includes FieldView Omega Analysis software; FieldLink communications software;
field patterns; color printer screening; quantify missed pts.; laptop computer; deluxe table; voice recognition; voice prompts; Advanced
13 programs std. support w/ full threshold; HT FieldView.
FieldView.
screening 30°, central optional printer threshold-related suprathreshold; 11 lbs., compact, easy to use; connects to any PC or purchase w/touch screen
field, suprathreshold, full full threshold; fast threshold controller; full database for patient management, output range 540-590nm,
& fast threshold alignment controls for patient comfort.
Central visual field test for External color inkjet n/a Normative database; easy to interpret report w/mapping, change-over-time
CNV determination. analysis & reliability indices.
central 30º, full 50°, peripheral 30º - use any printer via PC central threshold, Instrument is controlled via PC, which allows for easy networking in your office and
50º, macula 10º, glaucoma 22º/50º, Medmont Flicker Perimetry integration with your EMR or PM software. Software allows you to view exams in 2D
neurological 50º, quickscan 22º/30º, or 3D, in color or greyscale, overlay retinal images over visual field exams (optional).
driving 50º/80º, binocular 30º/40º, Utilizes previous exams from patients to reduce test time and gives detailed
binocular driving test 160º, spatially adaptive regression reports or patient history. Customize printouts for your need.
test 50º; customize any test or build your own
Comentarios a estos manuales